Draw/line
Home / Guides / Using your pen

Using your pen: missed doses, storage and when to throw it away

How to use your pen, step by step, and the label’s own rules for a missed dose, storage and throwing it away. Every line is quoted from the FDA label and the pen’s Instructions for Use.

Quoted from FDA labels on DailyMed · Checked

Your prescriber sets your dose. This page covers handling the product, not how much to take. Quotes are the label’s exact words; when a label gives no rule, we say so instead of guessing. Labels change, so check the leaflet in your box too. Some pen leaflets also say to wipe the seal before a new needle: see alcohol pads before an injection.

Your first week with a new pen

A short checklist. Each line comes from a pen leaflet, so it holds for most pens; your own leaflet is the one to follow.

  1. Get shown how to use your pen before the first injection. The Ozempic Instructions for Use says: Do not use your pen without proper training from your healthcare provider.
  2. Read the leaflet in the box. It is the Instructions for Use for your exact pen. The Ozempic Instructions for Use says: Read these instructions carefully before using your OZEMPIC® pen.
  3. Check the name and strength on the pen match your prescription. The Ozempic Instructions for Use says: Check the name and colored label of your pen, to make sure that it contains OZEMPIC.
  4. Write down the day you first use the pen, and the day to throw it away. The Ozempic Instructions for Use says: Write the disposal date on your calendar.
  5. Have a sharps container ready before the first injection. The Ozempic Instructions for Use says: Put your used OZEMPIC pen and needle in a FDA-cleared sharps disposal container right away after use.
  6. Find your pen’s missed-dose rule in its card below, so you know it before you need it.
  7. Keep the pen to yourself, even with a new needle. The Ozempic Instructions for Use says: Do not share your OZEMPIC pen with other people, even if the needle has been changed.

Questions to ask your pharmacist

Pharmacists can show you the pen in your hand. These questions cover what the leaflet says to ask about.

  1. Is this the pen and strength my prescriber ordered? The Ozempic Instructions for Use says: Check the name and colored label of your pen, to make sure that it contains OZEMPIC.
  2. Can you show me how to use this pen, step by step? The Ozempic Instructions for Use says: Do not use your pen without proper training from your healthcare provider.
  3. Which needles fit my pen, and do I need to buy more? The Ozempic Instructions for Use says: For needle compatibility information, talk to your healthcare professional.
  4. What do I do if I miss a dose?
  5. How do I store it, and when do I throw it away? The Ozempic Instructions for Use says: Keep OZEMPIC away from heat and out of the light.
  6. Where can I get rid of used needles and pens here? The Ozempic Instructions for Use says: There may be state or local laws about how you should throw away used needles and syringes.
  7. I cannot see the numbers well. Who can help me? The Ozempic Instructions for Use says: If you are blind or have poor eyesight and cannot read the dose counter on the pen, do not use this pen without help.

Quoted from the Ozempic Instructions for Use (Revised: June/2026) on DailyMed. Sharps disposal rules by state: FDA safe sharps disposal.

Find your pen

GLP-1 medicines

Wegovy (semaglutide)

single-dose pen · single-dose prefilled syringe with integrated needle · single-patient-use dial pen (WEGOVY FlexTouch), 4 fixed doses per pen

The label lists it as taken once weekly. Your prescriber sets your dose and schedule.

  • Missed a dose? The label says: If one dose of WEGOVY injection is missed and the next scheduled dose is:
    • more than 2 days away, administer WEGOVY injection as soon as possible.
    • less than 2 days away, do not administer the WEGOVY injection dose. Resume dosing on the regularly scheduled day of the week.
    If 2 or more consecutive doses of WEGOVY injection are missed, reinitiate dosage escalation at a lower dosage to reduce the risk of gastrointestinal adverse reactions. The patient guide adds: If you miss doses of WEGOVY for 2 or more consecutive weeks, contact your healthcare provider to talk about how to restart your treatment. If you are unsure, call your pharmacist.
  • After first use: After first use, WEGOVY FlexTouch single-patient-use pen can be stored for 56 days between 15°C to 30°C (59°F to 86°F) or in a refrigerator 2°C to 8°C (36°F to 46°F).
  • Throw away: Discard the WEGOVY pen or syringe after use.
  • Throw away: Throw away if the WEGOVY FlexTouch pen if it has been frozen, has been exposed to light or temperatures above 86°F (30°C), or has been out of the refrigerator for 56 days or longer.
  • Throw away: After having injected all four doses, there may still be medicine left in the pen. The pen should be thrown away (disposed of).
  • Never into a syringe: Never use a syringe to withdraw medicine from your pen.
  • Needles: NovoFine Plus 32G 4 mm disposable needles are included with your WEGOVY FlexTouch pen.
How to use it: Wegovy single-dose pen
  1. Check the pen. Check your WEGOVY pen. Do not use your WEGOVY pen if:
    • The WEGOVY medicine is not clear and colorless through the pen window.
    • The expiration date (EXP) has passed.
  2. Inject and hold. Pull the pen cap straight off your pen. Push the pen firmly against your skin and keep applying pressure until the yellow bar has stopped moving. You will hear 2 clicks during the injection.
  3. Throw the pen away. Safely dispose of the WEGOVY pen right away after each use. Put the used WEGOVY pen in an FDA-cleared sharps disposal container right away after use. Do not reuse the pen.
  4. Store it. Store the WEGOVY pen in the refrigerator between 36°F to 46°F (2°C to 8°C). If needed, before removing the pen cap, WEGOVY can be stored from 46°F to 86°F (8°C to 30°C) in the original carton for up to 28 days. Throw away the pen if WEGOVY has been frozen, has been exposed to light or temperatures above 86°F (30°C), or has been out of the refrigerator for 28 days or longer.

Quoted from the Wegovy single-dose pen Instructions for Use (Revised: November 2025), in the label on DailyMed. Your leaflet has the pictures for each step.

How to use it: Wegovy HD single-dose pen
  1. Check the pen. Check your WEGOVY pen. Do not use your WEGOVY pen if:
    • The WEGOVY medicine is not clear and colorless through the pen window.
    • The expiration date (EXP) has passed.
  2. Inject and hold. Pull the pen cap straight off your pen. Push the pen firmly against your skin and keep applying pressure until the yellow bar has stopped moving. You will hear 2 clicks during the injection.
  3. Throw the pen away. Safely dispose of the WEGOVY pen right away after each use. Put the used WEGOVY pen in an FDA-cleared sharps disposal container right away after use. Do not reuse the pen.
  4. Store it. Store the WEGOVY pen in the refrigerator between 36°F to 46°F (2°C to 8°C). If needed, before removing the pen cap, WEGOVY can be stored from 46°F to 86°F (8°C to 30°C) in the original carton for up to 28 days. Throw away the pen if WEGOVY has been frozen, has been exposed to light or temperatures above 86°F (30°C), or has been out of the refrigerator for 28 days or longer or after use.

Quoted from the Wegovy HD single-dose pen Instructions for Use (Revised: 03/2026), in the label on DailyMed. Your leaflet has the pictures for each step.

How to use it: Wegovy FlexTouch pen
  1. Check the pen. Wash your hands with soap and water. Check that the medicine in your pen is clear and colorless. If the medicine looks cloudy, do not use the pen.
  2. Attach a new needle. Take a new needle, and tear off the paper tab. Push the needle straight onto the pen. Turn until it is on tight. The needle is covered by 2 caps. You must remove both caps.
  3. Check the flow. Before you inject your first dose with your new pen, check the medicine flow. Turn the dose selector until the dose counter shows the flow check symbol Make sure that the flow check symbol lines up with the dose pointer. A drop of medicine will appear at the needle tip.
  4. Set your dose. Turn the dose selector until the dose counter stops, and it shows your 2.4 mg dose. Do not set the dose by counting the number of clicks you hear.
  5. Inject and hold. Insert the needle into your skin as your healthcare provider has shown you. Make sure you can see the dose counter. Do not cover it with your fingers. Continue pressing the dose button while keeping the needle in your skin and count slowly to 6.
  6. Remove the needle and throw it away. Carefully unscrew the needle from the pen. Place the needle in an FDA-cleared sharps container right away to reduce the risk of needle sticks.
  7. Store it. Put the pen cap on your pen after each use to protect the medicine from light. Store the single-patient-use WEGOVY FlexTouch pen without an injection needle attached. Throw away if the single-patient-use WEGOVY FlexTouch pen has been frozen, has been exposed to light or temperatures above 86°F (30°C), or has been out of the refrigerator for 56 days or longer.

Quoted from the Wegovy FlexTouch pen Instructions for Use (Revised 06//2026), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: WEGOVY (semaglutide) injection / WEGOVY tablets, Novo Nordisk (DailyMed SPL), label dated June 2026. Quotes checked against it on .

Ozempic (semaglutide)

single-patient-use dial pen (multi-dose) · single-dose prefilled syringe

The label lists it as taken once weekly. Your prescriber sets your dose and schedule.

  • Setting the dose: If you select the wrong dose, you can turn the dose selector forward or backwards to the correct dose.
  • Missed a dose? The label says: If a dose is missed, administer OZEMPIC as soon as possible within 5 days after the missed dose. If more than 5 days have passed, skip the missed dose and administer the next dose on the regularly scheduled day. If you are unsure, call your pharmacist.
  • After first use: After first use of the OZEMPIC pen, the pen can be stored for 56 days at controlled room temperature 15°C to 30°C (59°F to 86°F) or in a refrigerator 2°C to 8°C (36°F to 46°F).
  • Never into a syringe: Never use a syringe to withdraw OZEMPIC from your pen.
  • Needles: NovoFine Plus 32G 4 mm disposable needles are included with your OZEMPIC pen.
How to use it: Ozempic pen
  1. Check the pen. Check the name and colored label of your pen, to make sure that it contains OZEMPIC. Check that the OZEMPIC medicine in your pen is clear and colorless. If OZEMPIC looks cloudy or contains particles, do not use the pen.
  2. Attach a new needle. Take a new needle, and tear off the paper tab. Push the needle straight onto the pen. Turn until it is on tight. The needle is covered by 2 caps. You must remove both caps.
  3. Check the flow. Check the OZEMPIC flow before the first injection with each new pen only. Turn the dose selector until the dose counter shows the flow check symbol Hold the pen with the needle pointing up. A drop of OZEMPIC will appear at the needle tip.
  4. Set the dose your prescriber gave you. Make sure you know the dose of OZEMPIC you should use. The dashed line in the dose counter will guide you to your dose. The selected dose must line up exactly with the dose pointer to make sure that you get a correct dose. Do not set the dose by counting the number of clicks you hear.
  5. Inject and hold. Insert the needle into your skin as your healthcare provider has shown you. Press and hold down the dose button until the dose counter shows 0. Count 6 seconds while keeping the dose button pressed.
  6. Remove the needle and throw it away. Carefully remove the needle from the pen. Place the needle in a sharps disposal container right away to reduce the risk of needle sticks.
  7. Store it. Put the pen cap on your pen after each use to protect OZEMPIC from light. Store your pen in use for 56 days at room temperature between 59ºF to 86ºF (15ºC to 30ºC) or in a refrigerator between 36°F to 46°F (2°C to 8°C). The OZEMPIC pen you are using should be disposed of (thrown away) after 56 days, even if it still has OZEMPIC left in it.

Quoted from the Ozempic pen Instructions for Use (Revised: June/2026), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: OZEMPIC (semaglutide) injection, Novo Nordisk (DailyMed SPL), label dated June 2026. Quotes checked against it on .

Zepbound (tirzepatide)

single-dose pen (autoinjector style, needle attached) · single-dose vial · multi-dose vial (4 doses per vial) · single-patient-use KwikPen (multi-dose, 4 fixed doses)

The label lists it as taken once weekly. Your prescriber sets your dose and schedule.

  • Missed a dose? The label says: If a dose is missed, instruct patients to administer ZEPBOUND as soon as possible within 4 days (96 hours) after the missed dose. If more than 4 days have passed, skip the missed dose and administer the next dose on the regularly scheduled day. If you are unsure, call your pharmacist.
  • After first use: Store opened (in-use) multi-dose vial or single-patient-use KwikPen in the original carton in the refrigerator at 2°C to 8°C (36°F to 46°F) or at room temperature [up to 30°C (86°F)].
  • Throw away: Discard single-dose pen and single-dose vial after a total of 21 days at room temperature.
  • Throw away: Throw away opened multi-dose vial or single-patient-use KwikPen after a total of 30 days at room temperature, 30 days after first use, or after taking 4 weekly doses, even if there is medicine left in it.
  • Throw away: Throw away all opened vials after use, even if there is medicine left in the vial.
  • Never into a syringe: Do not transfer ZEPBOUND from your Pen into a syringe.
  • Needles: Note: The needle and syringe are not included.
How to use it: Zepbound single-dose pen
  1. Check the pen. Check the pen label to make sure you have the right medicine and dose, and that it has not expired. Inspect the pen to make sure that it is not damaged.
  2. Inject and hold. Pull the gray base cap straight off and throw it away in your household trash. Place clear base on skin, then unlock Press and hold the purple injection button for up to 10 seconds.
  3. Throw the pen away. Put your used pen in an FDA-cleared sharps disposal container right away after use.
  4. Store it. Store your pen in the refrigerator between 36°F to 46°F (2°C to 8°C). You may store your pen at room temperature up to 86°F (30°C) for up to a total of 21 days. Do not freeze your pen.

Quoted from the Zepbound single-dose pen Instructions for Use (Revised: April 2026), in the label on DailyMed. Your leaflet has the pictures for each step.

How to use it: Zepbound KwikPen
  1. Check the pen. Inspect the Pen and label. ZEPBOUND should be colorless to slightly yellow.
  2. Attach a new needle. Wipe the red inner seal with an alcohol swab. Always use a new pen needle for each injection to help prevent infections and blocked needles. Push the capped pen needle straight onto the Pen and twist the pen needle on until it is tight.
  3. Check the flow. Prime before each weekly injection. Slowly turn the dose knob until you hear 2 clicks and the extended line is shown in the dose window. Your Pen has been primed if a small amount (a drop) of medicine comes out of the tip of the pen needle.
  4. Set the dose. Turn the dose knob all the way until it stops AND the icon is in the dose window. Do not count clicks as you select the dose.
  5. Inject and hold. Insert the needle into your skin. Inject the medicine by pushing the dose knob in until it stops then slowly count to 5 while holding the dose knob. The icon must be shown in the dose window before removing the needle.
  6. Remove the needle and throw it away. Carefully replace the outer needle shield. Unscrew the capped needle and put the needle in a sharps container (see “Disposing of ZEPBOUND KwikPen and pen needles” section).
  7. Store it. You may store your used Pen at room temperature up to 86°F (30°C) after your injection. Throw away the Pen 30 days after first use even though the Pen has medicine left in it. Throw away the Pen after receiving 4 weekly doses.

Quoted from the Zepbound KwikPen Instructions for Use (Revised: January 2026), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: ZEPBOUND (tirzepatide) injection, Eli Lilly (DailyMed SPL), label dated August 2026. Quotes checked against it on .

Mounjaro (tirzepatide)

single-dose pen (autoinjector style, needle attached) · single-dose vial · multi-dose vial (4 doses per vial) · single-patient-use KwikPen (multi-dose, 4 fixed doses)

The label lists it as taken once weekly. Your prescriber sets your dose and schedule.

  • Missed a dose? The label says: If a dose is missed, instruct patients to administer MOUNJARO as soon as possible within 4 days (96 hours) after the missed dose. If more than 4 days have passed, skip the missed dose and administer the next dose on the regularly scheduled day. If you are unsure, call your pharmacist.
  • After first use: Store opened (in-use) multi-dose vial or single-patient-use KwikPen in the original carton in the refrigerator at 2°C to 8°C (36°F to 46°F) or at room temperature [up to 30°C (86°F)].
  • Throw away: Discard the single-dose pen or single-dose vial after a total of 21 days at room temperature.
  • Throw away: Throw away opened multi-dose vial or single-patient-use KwikPen after a total of 30 days at room temperature, 30 days after first use, or after taking 4 weekly doses, even if there is medicine left in it.
  • Throw away: Throw away all opened vials after use, even if there is medicine left in the vial.
  • Never into a syringe: Do not transfer MOUNJARO from your Pen into a syringe.
  • Needles: Note: The needle and syringe are not included.
How to use it: Mounjaro single-dose pen
  1. Check the pen. Check the Pen label to make sure you have the right medicine and dose, and that it has not expired. Inspect the Pen to make sure that it is not damaged.
  2. Inject and hold. Pull the gray base cap straight off and throw it away in your household trash. Place clear base on skin, then unlock Press and hold the purple injection button for up to 10 seconds.
  3. Throw the pen away. Put your used Pen in an FDA-cleared sharps disposal container right away after use.
  4. Store it. Store your Pen in the refrigerator between 36°F to 46°F (2°C to 8°C). You may store your Pen at room temperature up to 86°F (30°C) for up to a total of 21 days. Do not freeze your Pen.

Quoted from the Mounjaro single-dose pen Instructions for Use (Revised: April 2026), in the label on DailyMed. Your leaflet has the pictures for each step.

How to use it: Mounjaro KwikPen
  1. Check the pen. Inspect the Pen and label. MOUNJARO should be colorless to slightly yellow.
  2. Attach a new needle. Wipe the red inner seal with an alcohol swab. Always use a new pen needle for each injection to help prevent infections and blocked needles. Push the capped pen needle straight onto the Pen and twist the pen needle on until it is tight.
  3. Check the flow. Prime before each weekly injection. Slowly turn the dose knob until you hear 2 clicks and the extended line is shown in the dose window. Your Pen has been primed if a small amount (a drop) of medicine comes out of the tip of the pen needle.
  4. Set the dose. Turn the dose knob all the way until it stops AND the icon is in the dose window. Do not count clicks as you select the dose.
  5. Inject and hold. Insert the needle into your skin. Inject the medicine by pushing the dose knob in until it stops then slowly count to 5 while holding the dose knob. The icon must be shown in the dose window before removing the needle.
  6. Remove the needle and throw it away. Carefully replace the outer needle shield. Unscrew the capped needle and put the needle in a sharps container (see "Disposing of MOUNJARO KwikPen and pen needles" section).
  7. Store it. You may store your used Pen at room temperature up to 86°F (30°C) after your injection. Throw away the Pen 30 days after first use even though the Pen has medicine left in it. Throw away the Pen after receiving 4 weekly doses.

Quoted from the Mounjaro KwikPen Instructions for Use (Revised: January 2026), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: MOUNJARO (tirzepatide) injection, Eli Lilly (DailyMed SPL), label dated August 2026. Quotes checked against it on .

Saxenda (liraglutide)

single-patient-use dial-a-dose pen

The label lists it as taken once daily. Your prescriber sets your dose and schedule.

  • Setting the dose: If you select the wrong dose, you can turn the dose selector forward or backwards to the correct dose.
  • Missed a dose? The label says: If a dose is missed, resume the once-daily regimen as prescribed with the next scheduled dose. Do not administer an extra dose or increase the dose to make up for the missed dose. If more than 3 days have passed since the last Saxenda dose, the label says to restart at the starting dose and follow the step-up schedule again, to lower the risk of stomach and bowel side effects. Ask your prescriber how to restart. If you are unsure, call your pharmacist.
  • After first use: After initial use of the SAXENDA pen, the pen can be stored for 30 days at controlled room temperature 59°F to 86°F (15°C to 30°C) or in a refrigerator 36°F to 46°F (2°C to 8°C).
  • Throw away: The Saxenda pen you are using should be thrown away after 30 days, even if it still has Saxenda left in it.
  • Never into a syringe: Never use a syringe to withdraw Saxenda from your pen.
  • Needles: Pen needles are not included with your Saxenda pen.
How to use it: Saxenda pen
  1. Check the pen. Check the name and colored label of your pen, to make sure that it contains Saxenda. Check that Saxenda in your pen is clear and colorless. If Saxenda looks cloudy, do not use the pen.
  2. Attach a new needle. Take a new needle, and tear off the paper tab. Push the needle straight onto the pen. Turn until it is on tight. Pull off the inner needle cap and throw it away.
  3. Check the flow. Check the Saxenda flow before your first injection with each new pen. Turn the dose selector until the dose counter shows the flow check symbol Hold the pen with the needle pointing up. A drop of Saxenda will appear at the needle tip.
  4. Set the dose your prescriber gave you. Make sure you know the dose of Saxenda you should use. Do not set the dose by counting the number of clicks you hear.
  5. Inject and hold. Insert the needle into your skin as your healthcare provider has shown you. Press and hold down the dose button until the dose counter shows 0. Keep the needle in your skin after the dose counter has returned to 0 and count slowly to 6.
  6. Remove the needle and throw it away. Carefully remove the needle from the pen. Place the needle in a sharps container right away to reduce the risk of needle sticks.
  7. Store it. Put the pen cap on your pen after each use to protect Saxenda from light. Store your pen in use for 30 days at 59ºF to 86ºF (15ºC to 30ºC) or in a refrigerator at 36°F to 46°F (2°C to 8°C). The Saxenda pen you are using should be thrown away after 30 days, even if it still has Saxenda left in it.

Quoted from the Saxenda pen Instructions for Use (Revised: 06/2026), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: SAXENDA (liraglutide) injection, Novo Nordisk (DailyMed SPL), label dated February 2026. Quotes checked against it on .

Victoza (liraglutide)

single-patient-use dial pen (multi-dose)

The label lists it as taken once daily. Your prescriber sets your dose and schedule.

  • Setting the dose: Turn the dose selector until your needed dose lines up with the pointer
  • Missed a dose? The label says: Instruct patients who miss a dose of VICTOZA to resume the once daily dosage regimen as prescribed with the next scheduled dose. Do not administer an extra dose or increase the dose to make up for the missed dose. If you are unsure, call your pharmacist.
  • After first use: After first use of the VICTOZA pen, the pen can be stored for 30 days at controlled room temperature 59°F to 86°F (15°C to 30°C) or in a refrigerator 36°F to 46°F (2°C to 8°C).
  • Throw away: Throw away a used Victoza pen 30 days after you start using it, even if some medicine is left in the pen.
  • Throw away: If Victoza is stored outside of refrigeration (by mistake) prior to first use, it should be used or thrown away within 30 days.
  • Needles: Pen needles not included
How to use it: Victoza pen
  1. Check the pen. Check pen label before each use to make sure it is your Victoza pen. The liquid should be clear, colorless and free of particles. If not, do not use.
  2. Attach a new needle. Remove protective tab from outer needle cap. Push outer needle cap containing the needle straight onto the pen, then screw needle on until secure. Pull off inner needle cap and throw away.
  3. Check the flow. This step is done only One Time for each new pen and is Only required the first time you use a new pen. Turn dose selector until flow check symbol (--) lines up with pointer Hold pen with needle pointing up. Repeat steps C and D, up to 6 times, until a drop of Victoza appears at the needle tip.
  4. Set the dose your prescriber gave you. Be sure that you know the dose of Victoza that is prescribed for you. Turn the dose selector until your needed dose lines up with the pointer Do not set the dose by counting the number of clicks you hear.
  5. Inject and hold. Insert needle into your skin using the injection technique shown to you by your healthcare provider. Press down on the center of the dose button to inject until 0 mg lines up with the pointer Keep the dose button pressed down and make sure that you keep the needle under the skin for a full count of 6 seconds to make sure the full dose is injected.
  6. Remove the needle and throw it away. Carefully put the outer needle cap over the needle (See Figure Q). Unscrew the needle. Put your used VICTOZA pen and needles in a FDA-cleared sharps disposal container right away after use.
  7. Store it. After removing the needle, put the pen cap on your Victoza pen and store your Victoza pen without the needle attached (See Figure R). Store your Victoza pen at room temperature between 59ºF to 86ºF (15ºC to 30ºC), or in a refrigerator between 36ºF to 46ºF (2°C to 8°C). Use a Victoza pen for only 30 days.

Quoted from the Victoza pen Instructions for Use (Revised: 02/2025), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: VICTOZA (liraglutide) injection, Novo Nordisk (DailyMed SPL), label dated October 2025. Quotes checked against it on .

Trulicity (dulaglutide)

single-dose pen (needle attached, autoinjector style)

The label lists it as taken once weekly. Your prescriber sets your dose and schedule.

  • Missed a dose? The label says: If a dose is missed, instruct patients to administer the dose as soon as possible if there are at least 3 days (72 hours) until the next scheduled dose. If less than 3 days remain before the next scheduled dose, skip the missed dose If you are unsure, call your pharmacist.
  • After first use: Not applicable (single-dose pen, used once).
  • Throw away: Each Pen should only be used 1 time.
  • Needles: Needle is built into the single-dose pen (IFU: 'Do not touch the needle'); no separate needles needed.
How to use it: Trulicity single-dose pen
  1. Check the pen. Check the Pen label to make sure you have the right medicine and it has not expired. Check the Pen to make sure that it is not damaged and inspect the medicine to make sure it is not cloudy, discolored or has particles in it.
  2. Inject and hold. Unlock by turning the Lock Ring. Press and hold the green Injection Button. Continue holding the Clear Base firmly against your skin until you hear a second click.
  3. Throw the pen away. Remove the Pen from your skin. Put your used Pens in a FDA-cleared sharps disposal container right away after use.
  4. Store it. Store your Pen in the refrigerator between 36°F to 46°F (2°C to 8°C). You may store your Pen at room temperature below 86°F (30°C) for up to a total of 14 days. Do not freeze your Pen.

Quoted from the Trulicity single-dose pen Instructions for Use (Revised: 11/2022), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: TRULICITY (dulaglutide) injection, Eli Lilly (DailyMed SPL), label dated June 2026. Quotes checked against it on .

Bone-building medicines

Forteo (teriparatide)

single-patient-use prefilled pen (delivery device), 28 daily doses

The label lists it as taken once daily. Your prescriber sets your dose and schedule.

  • Missed a dose? This label gives no missed-dose rule. Ask your prescriber or pharmacist what to do, and do not double up.
  • After first use: When using FORTEO, minimize the time out of the refrigerator; deliver the dose immediately following removal from the refrigerator.
  • Throw away: Throw away the device 28 days after first use.
  • Never into a syringe: Do not transfer the medicine from the FORTEO delivery device to a syringe. This can result in taking the wrong dose of FORTEO.
  • Needles: Needles not included
How to use it: Forteo pen
  1. Check the pen. Check the FORTEO delivery device label to make sure you have the right medicine and that it has not expired. Do not use if the FORTEO delivery device looks damaged, if the medicine in the cartridge is not clear and colorless, or if it has particles in it.
  2. Attach a new needle. Push needle straight onto medicine cartridge. Screw on needle clockwise until firmly attached. Pull off large needle cover and save it.
  3. Set dose. Pull out black injection button until it stops. Check to make sure red stripe shows.
  4. Inject and hold. Gently hold a fold of skin on your thigh or abdomen and insert needle straight into skin. Push in black injection button until it stops. Hold it in and count to 5 slowly.
  5. Remove the needle and throw it away. Put large needle cover on needle. Pull off needle and throw away in a puncture-resistant container.
  6. Store it. Right after use, place FORTEO delivery device in the refrigerator. Store the FORTEO delivery device with the white cap on. Throw away the FORTEO delivery device 28 days after first use, even if it is not completely empty.

Quoted from the Forteo pen Instructions for Use (Literature revised Jun 03, 2025), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: FORTEO (teriparatide) injection, Eli Lilly (DailyMed SPL), label dated August 2026. Quotes checked against it on .

Teriparatide (generic) (teriparatide)

single-patient-use prefilled pen (delivery device), 28 daily doses

The label lists it as taken once daily. Your prescriber sets your dose and schedule.

  • Missed a dose? This label gives no missed-dose rule. Ask your prescriber or pharmacist what to do, and do not double up.
  • After first use: When using Teriparatide Injection, USP, minimize the time out of the refrigerator; deliver the dose immediately following removal from the refrigerator.
  • Throw away: Throw away the device 28 days after first use.
  • Never into a syringe: Do not transfer the medicine from the Teriparatide Injection delivery device to a syringe. This can result in taking the wrong dose of Teriparatide Injection.
  • Needles: Needles not included
How to use it: Teriparatide pen (Teva)
  1. Check the pen. Check the Teriparatide Injection delivery device label to make sure you have the right medicine and that it has not expired. Do not use if the Teriparatide Injection delivery device looks damaged, if the medicine in the cartridge is not clear and colorless, or if it has particles in it.
  2. Attach a new needle. Push needle straight onto medicine cartridge. Screw on needle clockwise until firmly attached. Pull off large needle cover and save it.
  3. Set dose. Pull out black injection button until it stops. Check to make sure red stripe shows.
  4. Inject and hold. Gently hold a fold of skin on your thigh or abdomen and insert needle straight into skin. Push in black injection button until it stops. Hold it in and count to 5 slowly.
  5. Remove the needle and throw it away. Put large needle cover on needle. Pull off needle and throw away in a puncture-resistant container.
  6. Store it. Right after use, place Teriparatide Injection delivery device in the refrigerator. Store the Teriparatide Injection delivery device with the blue cap on. Throw away the Teriparatide Injection delivery device 28 days after first use, even if it is not completely empty.

Quoted from the Teriparatide pen (Teva) Instructions for Use (Rev. B 9/2026), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: TERIPARATIDE injection, Teva (DailyMed SPL), ANDA 208569, label dated October 2026. Quotes checked against it on .

Tymlos (abaloparatide)

single-patient-use prefilled pen, 30 daily doses

The label lists it as taken once daily. Your prescriber sets your dose and schedule.

  • Missed a dose? The label says: If you forget or cannot take TYMLOS at your usual time, take it as soon as you can on that day. If you are unsure, call your pharmacist.
  • After first use: After first use, store for up to 30 days at 20°C to 25°C (68°F to 77°F).
  • Throw away: Advise patients that each TYMLOS pen can be used for up to 30 days, and after the 30-day use period, to discard the TYMLOS pen, even if it still contains unused solution
  • Never into a syringe: Do not transfer the medicine from the TYMLOS pen to a syringe. This can cause you to use the wrong dose of TYMLOS.
  • Needles: Pen needles are not included with your TYMLOS pen. You will need a prescription from your healthcare provider to get pen needles from your pharmacy.
How to use it: Tymlos pen
  1. Check the pen. Before using the pen always check the label to be sure it is your TYMLOS pen. Check the expiration date (Exp.) on the TYMLOS pen. The liquid should be clear, colorless, and free of particles; if not, do not use.
  2. Attach a new needle. Use a new pen needle for each injection. Keep the needle straight and screw it onto the pen until fixed; a secure fit is ensured even if there is no noticeable stop. Carefully pull off the inner pen needle cap and dispose of it.
  3. Check the flow. You only need to prime your pen on Day 1 for each new pen. Turn the dose knob on your TYMLOS pen away from you (clockwise) until it stops. You should see liquid come out of the needle tip.
  4. Set the dose on your TYMLOS pen. You do not have to measure your dose. The pen measures each dose of TYMLOS for you. Do not push the green injection button while setting your dose.
  5. Inject and hold. Insert the pen needle straight into your skin. Continue to press the green injection button while counting to 10. After counting to 10, release your finger from the green injection button and slowly remove the TYMLOS pen from the injection site by pulling the pen needle straight out.
  6. Remove the needle and throw it away. Carefully place the outer needle cap back on the pen needle. Unscrew the capped needle (like unscrewing a cap from a bottle). Put your used pen needles in a FDA-cleared sharps disposal container right away after use.
  7. Store it. Keep the pen cap on your TYMLOS pen between injections. After first use, store the TYMLOS pen for up to 30 days at room temperature between 68°F to 77°F (20°C to 25°C). Throw away your TYMLOS pen 30 days after first opening it even if it still contains unused medicine.

Quoted from the Tymlos pen Instructions for Use (Issued:04/2021), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: TYMLOS (abaloparatide) injection, Radius Health (DailyMed SPL), label dated August 2026. Quotes checked against it on .

Insulin pens

Lantus (insulin glargine)

10 mL multiple-dose vial · 3 mL single-patient-use SoloStar prefilled pen

The label lists it as taken once daily, at the same time every day. Your prescriber sets your dose and schedule.

  • Setting the dose: Turn the dose selector until the dose pointer lines up with your dose.
  • Missed a dose? This label gives no missed-dose rule. Ask your prescriber or pharmacist what to do, and do not double up.
  • After first use: 16.2 table: in-use vial 28 days, refrigerated or room temperature; in-use SoloStar pen 28 days, room temperature only (do not refrigerate).
  • Throw away: The LANTUS vial you are using should be thrown away after 28 days or if the expiration date has passed, even if it still has insulin left in it.
  • Never into a syringe: Do not use a syringe to remove LANTUS from your SoloStar disposable prefilled pen.
  • Needles: Needles are not included in the packs.
  • Low blood sugar: Mild episodes of hypoglycemia can usually be treated with oral carbohydrates.
How to use it: Lantus SoloStar pen
  1. Check the pen. Check the name and expiration date on the label of your pen. Check that the insulin is clear. Do not use the pen if the insulin looks cloudy, colored or contains particles.
  2. Attach a new needle. Take a new needle and peel off the protective seal. Keep the needle straight and screw it onto the pen until fixed. Pull off the inner needle cap and throw away.
  3. Check the flow. Check your pen and the needle to make sure they are working properly. Press the injection button all the way in. You may need to repeat this step up to 3 times before seeing insulin. First dial the small test amount shown in this step of your leaflet. It is a test, not your dose.
  4. Set the dose your prescriber gave you. Make sure a needle is attached and the dose is set to "0." Turn the dose selector until the dose pointer lines up with your dose.
  5. Inject and hold. Push the needle into your skin as shown by your healthcare provider. Place your thumb on the injection button. Then press all the way in and hold. Keep the injection button held in and when you see "0" in the dose window, slowly count to 10.
  6. Remove the needle and throw it away. Turn your pen several times with your other hand to remove the needle. Throw away the used needle in a puncture-resistant container
  7. Store it. Keep your pen at room temperature below 86°F (30°C). Do not put your pen back in the refrigerator. Only use your pen for up to 28 days after its first use.

Quoted from the Lantus SoloStar pen Instructions for Use (Revised: May 2025), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: LANTUS (insulin glargine) injection, Sanofi (DailyMed SPL), label dated June 2025. Quotes checked against it on .

Basaglar (insulin glargine)

3 mL single-patient-use KwikPen · 3 mL single-patient-use Tempo Pen (connected)

The label lists it as taken once daily, at the same time every day. Your prescriber sets your dose and schedule.

  • Missed a dose? This label gives no missed-dose rule. Ask your prescriber or pharmacist what to do, and do not double up.
  • After first use: 16.2 table: in-use, room temperature up to 86°F (30°C), 28 days, do not refrigerate.
  • Throw away: In-use BASAGLAR prefilled pens must be used within 28 days or be discarded, even if they still contain BASAGLAR.
  • Needles: Needles are not included.
  • Low blood sugar: Mild episodes of hypoglycemia can be treated with oral glucose.
How to use it: Basaglar KwikPen
  1. Check the pen. Check the Pen to make sure you are taking the right type of insulin. BASAGLAR should look clear and colorless. Do not use if it is cloudy, colored, or has particles or clumps in it.
  2. Attach a new needle. Push the capped Needle straight onto the Pen and twist the Needle on until it is tight. Pull off the Inner Needle Shield and throw it away.
  3. Check the flow. Prime before each injection. Hold your Pen with the Needle pointing up. You should see insulin at the tip of the Needle. First dial the small test amount shown in this step of your leaflet. It is a test, not your dose.
  4. Set the dose your prescriber gave you. Turn the Dose Knob to select the number of units you need to inject. Always check the number in the Dose Window to make sure you have dialed the correct dose.
  5. Inject and hold. Insert the Needle into your skin. Push the Dose Knob all the way in. Continue to hold the Dose Knob in and slowly count to 5 before removing the needle.
  6. Remove the needle and throw it away. Carefully replace the Outer Needle Shield. Unscrew the capped Needle and throw it away (see Disposing of Pens and Needles section below).
  7. Store it. Store the Pen you are currently using at room temperature [up to 86°F (30°C)] and away from heat and light. Throw away the Pen you are using after 28 days, even if it still has insulin left in it.

Quoted from the Basaglar KwikPen Instructions for Use (Instructions for Use revised: November 2022), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: BASAGLAR KwikPen / Tempo Pen (insulin glargine), Eli Lilly (DailyMed SPL), label dated June 2026. Quotes checked against it on .

Semglee (insulin glargine-yfgn)

10 mL multiple-dose vial · 3 mL single-patient-use prefilled pen

The label lists it as taken once daily, at the same time every day. Your prescriber sets your dose and schedule.

  • Missed a dose? This label gives no missed-dose rule. Ask your prescriber or pharmacist what to do, and do not double up.
  • After first use: 16.2 table: in-use vial 28 days, refrigerated or room temperature; in-use pen 28 days, room temperature only (do not refrigerate).
  • Throw away: The SEMGLEE vial you are using should be thrown away after 28 days or if the expiration date has passed, even if it still has insulin left in it.
  • Never into a syringe: Do not use a syringe to remove SEMGLEE from your disposable prefilled pen.
  • Needles: Needles are not included in the packs.
  • Low blood sugar: Mild episodes of hypoglycemia can usually be treated with oral carbohydrates.
How to use it: Semglee prefilled pen
  1. Check the pen. Check the name and expiration date on the label of your pen. Check that the insulin is clear Do not use the pen if the insulin looks cloudy, colored or contains particles.
  2. Attach a new needle. Take a new needle and peel off the protective seal Keep the needle straight and screw it onto the pen until fixed. Pull off the inner needle cap and throw away
  3. Check the flow. Check your pen and the needle to make sure they are working properly. When insulin comes out of the needle tip, your pen is working correctly. You may need to repeat this step up to 3 times before seeing insulin. First dial the small test amount shown in this step of your leaflet. It is a test, not your dose.
  4. Set the dose your prescriber gave you. Make sure a needle is attached and the dose is set to “0” Turn the dose selector until the dose pointer lines up with your dose
  5. Inject and hold. Push the needle into your skin as shown by your healthcare provider Place your thumb on the injection button. Slowly press all the way in and hold Keep the injection button held in and when you see 0 in the dose window, slowly count to 10
  6. Remove the needle and throw it away. Turn your pen several times with your other hand to remove the needle Throw away the used needle in a puncture-resistant container
  7. Store it. Keep your pen at room temperature below 86°F (30°C). Do not put your pen back in the refrigerator. Only use your pen for up to 28 days after its first use.

Quoted from the Semglee prefilled pen Instructions for Use (Revised: 03/2025), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: SEMGLEE (insulin glargine-yfgn) injection, Biocon Biologics (DailyMed SPL), label dated March 2025. Quotes checked against it on .

Toujeo (insulin glargine)

1.5 mL SoloStar single-patient-use prefilled pen (450 units) · 3 mL Max SoloStar single-patient-use prefilled pen (900 units)

The label lists it as taken once daily, at the same time every day. Your prescriber sets your dose and schedule.

  • Missed a dose? This label gives no missed-dose rule. Ask your prescriber or pharmacist what to do, and do not double up.
  • After first use: 16.2 table: in-use (opened), room temperature only (do not refrigerate), up to 86°F (30°C), 56 days; store with the cap on.
  • Throw away: Discard TOUJEO prefilled pen if it has been frozen.
  • Never into a syringe: Never transfer TOUJEO from the cartridges of the TOUJEO SoloStar or TOUJEO Max SoloStar prefilled pen into a syringe for administration
  • Needles: Needles are not included in the packs of TOUJEO SoloStar or TOUJEO Max SoloStar single-patient-use prefilled pen.
  • Low blood sugar: Mild episodes of hypoglycemia can be treated with oral glucose.
How to use it: Toujeo SoloStar pen
  1. Check the pen. Check the name and expiration date on the label of your pen. Check that the insulin is clear. Do not use the pen if the insulin looks cloudy, colored or contains particles.
  2. Attach a new needle. Take a new needle and peel off the protective seal. Keep the needle straight and screw it onto the pen until fixed. Pull off the inner needle cap and throw away.
  3. Check the flow. Press the injection button all the way in. When insulin comes out of the needle tip, your pen is working correctly. You may need to repeat this step up to 3 times before seeing insulin. First dial the small test amount shown in this step of your leaflet. It is a test, not your dose.
  4. Set the dose your prescriber gave you. Make sure a needle is attached and the dose is set to "0." Turn the dose selector until the dose pointer lines up with your dose. Always check the number in the dose window to make sure you dialed the correct dose.
  5. Inject and hold. Push the needle into your skin as shown by your healthcare provider. Place your thumb on the injection button. Then press all the way in and hold. Keep the injection button held in and when you see "0" in the dose window, slowly count to 5.
  6. Remove the needle and throw it away. Turn your pen several times with your other hand to remove the needle. Throw away the used needle in a puncture-resistant container
  7. Store it. Keep your pen at room temperature up to 86°F (30°C). Do not put your pen back in the refrigerator. Only use your pen for up to 56 days after its first use.

Quoted from the Toujeo SoloStar pen Instructions for Use (Revised: May 2025), in the label on DailyMed. Your leaflet has the pictures for each step.

How to use it: Toujeo Max SoloStar pen
  1. Check the pen. Check the name and expiration date on the label of your pen. Check that the insulin is clear. Do not use the pen if the insulin looks cloudy, colored or contains particles.
  2. Attach a new needle. Take a new needle and peel off the protective seal. Keep the needle straight and screw it onto the pen until fixed. Pull off the inner needle cap and throw away.
  3. Check the flow. Press the injection button all the way in. When insulin comes out of the needle tip, your pen is working correctly. You may need to repeat this step up to 6 times before seeing insulin. First dial the small test amount shown in this step of your leaflet. It is a test, not your dose.
  4. Set the dose your prescriber gave you. Make sure a needle is attached and the dose is set to "0." Turn the dose selector until the dose pointer lines up with your dose. Always check the number in the dose window to make sure you dialed the correct dose.
  5. Inject and hold. Push the needle into your skin as shown by your healthcare provider. Place your thumb on the injection button. Then press all the way in and hold. Keep the injection button held in and when you see "0" in the dose window, slowly count to 5.
  6. Remove the needle and throw it away. Turn your pen several times with your other hand to remove the needle. Throw away the used needle in a puncture-resistant container
  7. Store it. Keep your pen at room temperature up to 86°F (30°C). Do not put your pen back in the refrigerator. Only use your pen for up to 56 days after its first use.

Quoted from the Toujeo Max SoloStar pen Instructions for Use (Revised: May 2025), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: TOUJEO / TOUJEO Max (insulin glargine) injection 300 units/mL, Sanofi (DailyMed SPL), label dated May 2025. Quotes checked against it on .

Humalog (insulin lispro)

U-100: 10 mL and 3 mL multiple-dose vials, 3 mL KwikPen, Tempo Pen, Junior KwikPen, 3 mL cartridges · U-200: 3 mL single-patient-use KwikPen only

The label lists it as taken mealtime: within 15 minutes before a meal or immediately after a meal. Your prescriber sets your dose and schedule.

  • Setting the dose: Always check the number in the Dose Window to make sure you have dialed the correct dose.
  • Missed a dose? This label gives no missed-dose rule. Ask your prescriber or pharmacist what to do, and do not double up.
  • After first use: 16.2 table: in-use vials 28 days, refrigerated or room temperature; in-use pens and cartridges (including U-200 KwikPen) 28 days, room temperature only (do not refrigerate).
  • Throw away: When stored at room temperature, HUMALOG U-100 and U-200 can only be used for a total of 28 days, including both not in-use (unopened) and in-use (opened) storage time.
  • Never into a syringe: Do not transfer HUMALOG U-200 from the HUMALOG prefilled pens to a syringe. The markings on the insulin syringe will not measure the dose correctly and can result in overdosage and severe hypoglycemia
  • Needles: Needles not included
  • Low blood sugar: Mild episodes of hypoglycemia usually can be treated with oral glucose.
How to use it: Humalog KwikPen (U-100) and Humalog KwikPen (U-200)
  1. Check the pen. Check your Pen to make sure you are taking the right type of insulin. HUMALOG should look clear and colorless. Do not use if it is cloudy, colored, or has particles or clumps in it.
  2. Attach a new needle. Push the capped Needle straight onto the Pen and twist the Needle on until it is tight. Pull off the Inner Needle Shield and throw it away.
  3. Check the flow. Prime before each injection. Hold your Pen with the Needle pointing up. You should see insulin at the tip of the Needle. First dial the small test amount shown in this step of your leaflet. It is a test, not your dose.
  4. Set the dose your prescriber gave you. Turn the Dose Knob to select the number of units you need to inject. Always check the number in the Dose Window to make sure you have dialed the correct dose.
  5. Inject and hold. Insert the Needle into your skin. Push the Dose Knob all the way in. Continue to hold the Dose Knob in and slowly count to 5 before removing the Needle.
  6. Remove the needle and throw it away. Carefully replace the Outer Needle Shield. Unscrew the capped Needle and throw it away (see Disposing of Pens and Needles section).
  7. Store it. Store the Pen you are currently using at room temperature [up to 86°F (30°C)]. Throw away the HUMALOG Pen you are using after 28 days, even if it still has insulin left in it.

Quoted from the Humalog KwikPen (U-100) and Humalog KwikPen (U-200) Instructions for Use (Revised: July 2023), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: HUMALOG (insulin lispro) injection, Eli Lilly (DailyMed SPL), label dated June 2026. Quotes checked against it on .

Humulin R U-500 (insulin human (regular))

3 mL single-patient-use KwikPen (1,500 units); PI section 3 and 16 list only the KwikPen

The label lists it as taken two or three times daily, 30 minutes before a meal. Your prescriber sets your dose and schedule.

  • Missed a dose? This label gives no missed-dose rule. Ask your prescriber or pharmacist what to do, and do not double up.
  • After first use: 16.2 Table 2: in-use, room temperature up to 86°F (30°C), 28 days; do not refrigerate.
  • Throw away: When stored at room temperature, HUMULIN R U-500 KwikPen can only be used for a total of 28 days, including both not in-use (unopened) and in-use (opened) storage time.
  • Never into a syringe: DO NOT transfer HUMULIN R U-500 from the HUMULIN R U-500 KwikPen into any syringe for administration as overdose and severe hypoglycemia can occur
  • Needles: NEEDLES NOT INCLUDED
  • Low blood sugar: Mild episodes of hypoglycemia usually can be treated with oral glucose.
How to use it: Humulin R U-500 KwikPen
  1. Check the pen. Check the Pen to make sure you are taking the right type of insulin. HUMULIN R U-500 should look clear and colorless. Do not use if it is cloudy, colored, or has particles or clumps in it.
  2. Attach a new needle. Push the capped Needle straight onto the Pen and twist the Needle on until it is tight. Pull off the Inner Needle Shield and throw it away.
  3. Check the flow. Prime before each injection. Hold your Pen with the Needle pointing up. You should see insulin at the tip of the Needle. First dial the small test amount shown in this step of your leaflet. It is a test, not your dose.
  4. Set the dose your prescriber gave you. Turn the Dose Knob to select the number of units you need to inject. Always check the number in the Dose Window to make sure you have dialed the correct dose.
  5. Inject and hold. Insert the Needle into your skin. Push the Dose Knob all the way in. Continue to hold the Dose Knob in and slowly count to 5 before removing the Needle.
  6. Remove the needle and throw it away. Carefully replace the Outer Needle Shield. Unscrew the capped Needle and throw it away
  7. Store it. Store the Pen you are currently using at room temperature up to 86°F (30°C). Throw away the Pen you are using after 28 days, even if it still has insulin left in it.

Quoted from the Humulin R U-500 KwikPen Instructions for Use (Document revision date: July 2026), in the label on DailyMed. Your leaflet has the pictures for each step.

Source: HUMULIN R U-500 (insulin human) injection, Eli Lilly (DailyMed SPL), label dated July 2026. Quotes checked against it on .

Other prescribed autoinjectors

Vyleesi (bremelanotide)

single-dose autoinjector

The label lists it as taken as needed, at least 45 minutes before anticipated sexual activity; label limits: not more than one dose within 24 hours, more than 8 doses per month not recommended. Your prescriber sets your dose and schedule.

  • Missed a dose? This label gives no missed-dose rule. Ask your prescriber or pharmacist what to do, and do not double up.
  • After first use: Not applicable (single-dose).
  • Needles: Needle is inside the single-dose autoinjector; no separate needles.

Source: VYLEESI (bremelanotide injection), Cosette Pharmaceuticals (DailyMed SPL), label dated November 2026. Quotes checked against it on .

Switching from a pen to a vial?

A vial means measuring each dose with a syringe. Read switching from a GLP-1 pen to a vial and use the pen to vial calculator, which works from the dose on your vial prescription.

For research and educational use. Not medical advice. Your prescriber and pharmacist are the authority for your medicine.

Spot a mistake or an out-of-date fact? Report an error. We check every report against the sources.